Customization: | Available |
---|---|
Application: | Construction, Overhead, Underground, Industrial, Power Station |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 200/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Main Application
The cables are suitable for MV power applications, particularly for connections in transformer stations and power stations, between aerial lines and transformer stations. Aerial Bundle Cable, abbreviated as ABC, are wrapped with insulation, with the medium voltage variants also having an outer sheath. The cables lay up and twist multiple insulated single cores together - medium voltage ABC also tend to have a steel wire support running through the center for applications including street lighting and secondary pole to pole service cables. The cables also often used in temporary power installations in the construction industry. The insulation provides a protective barrier in the event of sparks or shorts.
2. Standards
IEC60502-2, AS/NZS 3599-1, AS/NZS 3599-2, GB/T14049 etc.
* Xinfeng Cable can also design and produce for special application requirement.
3. Characteristics
Voltage rating: 6kV-46kV
Operating temperature:
PVC: -15°C to +70°C PE: -40°C to +70°C XLPE: -40°C to +90°C
Minimum laying/installation temperature:
PVC: 0°C PE: -20°C XLPE: -20°C
4. Construction:
Type 1:
Type 2:
If the cable model you want is not in the list, please contact our sales team to get more. For full technical specifications and for details of the bare conductor, please refer to the datasheets or speak to our sales team for more advice.
5. Product Type Description:
Description | Chinese type | International type |
Aluminum conductor XLPE insulated aerial cable | JKLYJ/Q* | AAC/XLPE |
Aluminum alloy conductor XLPE insulated aerial cable | JKLHYJ/Q* | AAAC/XLPE |
Copper conductor XLPE insulated aerial cable | JKYJ | CU/XLPE |
Aluminum conductor XLPE insulated aerial cable | JKLYJ | AAC/XLPE |
Aluminum alloy conductor XLPE insulated aerial cable | JKLHYJ | AAAC/XLPE |
Aluminum Conductor Steel Reinforced core XLPE insulated aerial cable | JKLGYJ JKLGYJ/Q* | ACSR/XLPE |
Note: *: With Q Light type, without conductor screen.
6.Part Of Technical Parameter
Type 1:
Type | Nom. Conductor Cross Section mm² |
Max.DC Conductor Resistance At 20ºC Ω/km |
Approx.Min Thickness Conductor Screen mm |
Nom. Thickness Of Insulation mm |
Approx. OD mm |
Approx. Weight kg/km |
Minimum Breaking Load N |
Current-Carrying Capacity A |
CU/XLPE -35 |
50 | 0.399 | 0.5 | 9.3 | 27.9 | 964 | 16502 | 275 |
70 | 0.276 | 0.5 | 9.3 | 29.6 | 1186 | 23461 | 345 | |
95 | 0.199 | 0.6 | 9.3 | 31.4 | 1458 | 31759 | 415 | |
120 | 0.158 | 0.6 | 9.3 | 32.8 | 1747 | 39911 | 480 | |
150 | 0.128 | 0.6 | 9.3 | 34.4 | 2015 | 49505 | 550 | |
185 | 0.1021 | 0.6 | 9.3 | 35.9 | 2320 | 61846 | 630 | |
240 | 0.0777 | 0.6 | 9.3 | 38.2 | 2896 | 79823 | 745 | |
300 | 0.0619 | 0.6 | 9.3 | 40.5 | 3479 | 99788 | 860 | |
AAC/XLPE -35 |
50 | 0.641 | 0.5 | 9.3 | 27.9 | 664 | 7011 | 215 |
70 | 0.443 | 0.5 | 9.3 | 29.6 | 767 | 10345 | 265 | |
95 | 0.320 | 0.6 | 9.3 | 31.4 | 889 | 13727 | 325 | |
120 | 0.253 | 0.6 | 9.3 | 32.8 | 996 | 17339 | 375 | |
150 | 0.206 | 0.6 | 9.3 | 34.4 | 1122 | 21033 | 425 | |
185 | 0.164 | 0.6 | 9.3 | 35.9 | 1247 | 26732 | 490 | |
240 | 0.125 | 0.6 | 9.3 | 38.2 | 1472 | 34679 | 580 | |
300 | 0.100 | 0.6 | 9.3 | 40.5 | 1698 | 43349 | 665 | |
AAAC/XLPE -35 |
50 | 0.744 | 0.5 | 9.3 | 27.9 | 664 | 12569 | 210 |
70 | 0.514 | 0.5 | 9.3 | 29.6 | 767 | 17396 | 250 | |
95 | 0.371 | 0.6 | 9.3 | 31.4 | 889 | 23886 | 315 | |
120 | 0.294 | 0.6 | 9.3 | 32.8 | 996 | 30164 | 365 | |
150 | 0.239 | 0.6 | 9.3 | 34.4 | 1122 | 37706 | 410 | |
185 | 0.19 | 0.6 | 9.3 | 35.9 | 1247 | 46503 | 485 | |
240 | 0.145 | 0.6 | 9.3 | 38.2 | 1472 | 60329 | 565 | |
300 | 0.11 | 0.6 | 9.3 | 40.5 | 1698 | 75411 | 650 |
Note: Current-carrying capacity (A) : ambient temperature 25°C.
Type 2:
6.35/11(12) kV Aerial Bundled Cable metallic screened, AL/XLPE/CTS/PVC AS/NZS 3599.1
Number of cores x nominal cross section No.×mm² |
Phase conductor | Messenger conductor (Bare) | Approx. OD mm |
Approx. weight kg/km |
Continuous current rating at 40ºC ambient temp A |
|||||
Stranding No.×mm |
Nominal diameter of conductor mm |
Nom. thickness of insulation mm |
Maximum conductor resistance at 20°C Ω/km |
Stranding No.×mm |
Nominal sectional area mm² |
Minimum breaking load kN |
||||
3X50 + 1X50 | 7/3.05 | 8.1 | 3.4 | 0.641 | 7/3.00 | 50 | 60 | 46 | 2200 | 116 |
3X70 + 1X50 | 19/2.22 | 9.8 | 3.4 | 0.443 | 7/3.00 | 50 | 60 | 49 | 2500 | 173 |
3X95+ 1X50 | 19/2.55 | 11.4 | 3.4 | 0.320 | 7/3.00 | 50 | 60 | 52 | 2850 | 210 |
3X120 +1X50 | 19/2.85 | 12.8 | 3.4 | 0.253 | 7/3.00 | 50 | 60 | 55 | 3160 | 259 |
3X150 +1X50 | 19/3.15 | 14.4 | 3.4 | 0.206 | 7/3.00 | 50 | 60 | 58 | 3560 | 259 |
3X185+1X50 | 36/2.52 | 16.0 | 3.4 | 0.164 | 7/3.00 | 50 | 60 | 61 | 3990 | 365 |
3X240 +1X50 | 36/2.88 | 18.4 | 3.4 | 0.125 | 7/3.00 | 50 | 60 | 66 | 4710 | 500 |
12.7/22(24) kV Aerial Bundled Cable metallic screened, AL/XLPE/CTS/PVC AS/NZS 3599.1
Number of cores x nominal cross section No.×mm² |
Phase conductor | Messenger conductor (Bare) | Approx. OD mm |
Approx. weight kg/km |
Continuous current rating at 40ºC ambient temp A |
|||||
Stranding No.×mm |
Nominal diameter of conductor mm |
Nom. thickness of insulation mm |
Maximum conductor resistance at 20°C Ω/km |
Stranding No.×mm |
Nominal sectional area mm² |
Minimum breaking load kN |
||||
3X50 + 1X50 | 7/3.05 | 8.1 | 5.5 | 0.641 | 7/3.00 | 50 | 60 | 54 | 2746 | 116 |
3X70 + 1X50 | 19/2.22 | 9.8 | 5.5 | 0.443 | 7/3.00 | 50 | 60 | 57 | 3133 | 173 |
3X95+ 1X50 | 19/2.55 | 11.4 | 5.5 | 0.320 | 7/3.00 | 50 | 60 | 60 | 3513 | 210 |
3X120 +1X50 | 19/2.85 | 12.8 | 5.5 | 0.253 | 7/3.00 | 50 | 60 | 63 | 3900 | 259 |
3X150 +1X50 | 19/3.15 | 14.4 | 5.5 | 0.206 | 7/3.00 | 50 | 60 | 66 | 4300 | 259 |
3X185+1X50 | 36/2.52 | 16.0 | 5.5 | 0.164 | 7/3.00 | 50 | 60 | 69 | 4805 | 365 |
3X240 +1X50 | 36/2.88 | 18.4 | 5.5 | 0.125 | 7/3.00 | 50 | 60 | 74 | 5600 | 500 |
19/33(36) kV Aerial Bundled Cable metallic screened, AL/XLPE/CTS/PVC AS/NZS 3599.1
Number of cores x nominal cross section No.×mm² |
Phase conductor | Messenger conductor (Bare) | Approx. OD mm |
Approx. weight kg/km |
Continuous current rating at 40ºC ambient temp A |
|||||
Stranding No.×mm |
Nominal diameter of conductor mm |
Nom. thickness of insulation mm |
Maximum conductor resistance at 20°C Ω/km |
Stranding No.×mm |
Nominal sectional area mm² |
Minimum breaking load kN |
||||
3X50 + 1X50 | 7/3.05 | 8.1 | 8.0 | 0.641 | 7/3.00 | 50 | 60 | 64 | 3610 | 116 |
3X70 + 1X50 | 19/2.22 | 9.8 | 8.0 | 0.443 | 7/3.00 | 50 | 60 | 67 | 4016 | 173 |
3X95+ 1X50 | 19/2.55 | 11.4 | 8.0 | 0.320 | 7/3.00 | 50 | 60 | 70 | 4486 | 210 |
3X120 +1X50 | 19/2.85 | 12.8 | 8.0 | 0.253 | 7/3.00 | 50 | 60 | 73 | 4854 | 259 |
3X150 +1X50 | 19/3.15 | 14.4 | 8.0 | 0.206 | 7/3.00 | 50 | 60 | 76 | 5358 | 259 |
3X185+1X50 | 36/2.52 | 16.0 | 8.0 | 0.164 | 7/3.00 | 50 | 60 | 79 | 5912 | 365 |
3X240 +1X50 | 36/2.88 | 18.4 | 8.0 | 0.125 | 7/3.00 | 50 | 60 | 83 | 6710 | 500 |
6.35/11(12) kV Aerial Bundled Cable non-screened, Al/XLPE/HDPE AS/NZS 3599.2
Number of cores x nominal cross section No.×mm² |
Phase conductor | Messenger conductor(Bare) | Approx. completed cable OD mm |
Approx. weight kg/km |
Continuous current rating at 40ºC ambient temp A |
|||||
Nominal diameter of conductor mm |
Nominal thickness of insulation mm |
Nominal thickness of insulation screen mm |
Nominal thickness of sheath mm |
Maximum conductor resistance at 20°C Ω/km |
Stranding No.×mm |
Approx. OD mm |
||||
3x35 | 6.9 | 3.4 | 0.6 | 1.2 | 0.868 | 7/5.00 | 15.0 | 52.3 | 1470 | 165 |
3x50 | 8.1 | 3.4 | 0.6 | 1.2 | 0.641 | 7/5.00 | 15.0 | 53.5 | 1580 | 200 |
3x70 | 9.8 | 3.4 | 0.6 | 1.2 | 0.443 | 7/5.00 | 15.0 | 56.7 | 1850 | 245 |
3x95 | 11.4 | 3.4 | 0.6 | 1.2 | 0.320 | 7/5.00 | 15.0 | 60.2 | 2180 | 300 |
3x120 | 12.8 | 3.4 | 0.6 | 1.2 | 0.253 | 19/3.65 | 18.2 | 66.2 | 2640 | 345 |
3x150 | 14.4 | 3.4 | 0.6 | 1.2 | 0.206 | 19/3.65 | 18.2 | 69.0 | 2960 | 390 |
3x185 | 16.0 | 3.4 | 0.6 | 1.2 | 0.164 | 19/3.65 | 18.2 | 72.4 | 3380 | 450 |
12.7/22(24) kV Aerial Bundled Cable metallic screened Al/XLPE/CWS/HDPE AS/NZS 3599.1
Number of cores x nominal cross section No.×mm² |
Phase Conductor | Messenger conductor(Bare) | Approx. completed cable OD mm |
Approx. weight kg/km |
Continuous current rating at 40ºC ambient temp A |
||||||
Nominal diameter of conductor mm |
Nominal thickness of insulation mm |
Nominal thickness of insulation screen mm |
Nominal thickness of sheath mm |
Maximum conductor resistance at 20°C Ω/km |
Copper wire screen No.×mm |
Stranding No.×mm |
Approx. OD mm |
||||
Light duty screen | |||||||||||
3x35 | 6.9 | 5.5 | 0.6 | 1.8 | 0.868 | 25/0.85 | 7/2.00 | 6.0 | 62.8 | 2340 | 150 |
3x50 | 8.1 | 5.5 | 0.6 | 1.8 | 0.641 | 25/0.85 | 19/2.00 | 10.0 | 68.5 | 2780 | 185 |
3x70 | 9.8 | 5.5 | 0.6 | 1.8 | 0.443 | 25/0.85 | 19/2.00 | 10.0 | 71.8 | 3100 | 230 |
3x95 | 11.4 | 5.5 | 0.6 | 1.9 | 0.320 | 25/0.85 | 19/2.00 | 10.0 | 75.6 | 3510 | 280 |
3x120 | 12.8 | 5.5 | 0.6 | 1.9 | 0.253 | 25/0.85 | 19/2.00 | 10.0 | 78.6 | 3850 | 320 |
3x150 | 14.4 | 5.5 | 0.6 | 2.0 | 0.206 | 25/0.85 | 19/2.00 | 10.0 | 81.8 | 4240 | 365 |
3x185 | 16.0 | 5.5 | 0.6 | 2.0 | 0.164 | 25/0.85 | 19/2.00 | 10.0 | 85.2 | 4710 | 415 |
Heavy duty screen | |||||||||||
3x35 | 6.9 | 5.5 | 0.6 | 1.8 | 0.868 | 40/0.85 | 7/2.00 | 6.0 | 62.8 | 2600 | 155 |
3x50 | 8.1 | 5.5 | 0.6 | 1.8 | 0.641 | 23/1.35 | 19/2.00 | 10.0 | 70.5 | 3350 | 185 |
3x70 | 9.8 | 5.5 | 0.6 | 1.8 | 0.443 | 32/1.35 | 19/2.00 | 10.0 | 73.8 | 4030 | 230 |
3x95 | 11.4 | 5.5 | 0.6 | 1.9 | 0.320 | 38/1.35 | 19/2.00 | 10.0 | 77.6 | 4680 | 280 |
3x120 | 12.8 | 5.5 | 0.6 | 1.9 | 0.253 | 38/1.35 | 19/2.00 | 10.0 | 80.6 | 5020 | 320 |
3x150 | 14.4 | 5.5 | 0.6 | 2.0 | 0.206 | 38/1.35 | 19/2.00 | 10.0 | 83.8 | 5410 | 365 |
3x185 | 16.0 | 5.5 | 0.6 | 2.0 | 0.164 | 38/1.35 | 19/2.00 | 10.0 | 87.2 | 5880 | 415 |
Packaging Mode 1:Wooden Drum Packing,suitable for small cross section cable.Packing length about 500 meters.
Packaging Mode 2:Steel Frame Wooden Drum Packing,suitable for big cross section cable.Packing length about 2000 meters.
Xinfeng Cable Co., Ltd. is a research and development, production, sales in one of the well-known wire and cable enterprises, with a complete and scientific quality management system, advanced technical team support, strong sales and after-sales service.
Henan Xinfeng Cable Co., LTD., founded in 1996, with a registered capital of 210 million CNY, covers a total area of 50,000 square meters, the existing staff of 586 people, including a variety of technical personnel more than 80 people, with a university degree 60 people, the company has the current domestic advanced production equipment and testing equipment, including more than 200 sets of advanced cable production equipment. And spend tens of millions to purchase the most complete cable testing equipment.
In 2012, the company took the lead in the cable industry through the ISO9001 international quality system certification, ISO14001 occupational safety and health certification system, 18001 environmental management certification, national CCC compulsory certification and other qualifications, and through the European safety product CE certification, European environmental protection ROSH certification, SGS environmental protection product testing certification. In 20 years of development, it has formed an annual production capacity of 1.5 billion CNY for overhead insulated wires, high and low voltage cables, BV cables and other products, and constantly improve and expand the research and development and production field of cable products.
At present, the company is mainly engaged in the system design, development, manufacturing, marketing and service of more than 1000 kinds of cables in four categories: overhead wire, power cable, electrical equipment wire and cable, and special cable. Products are widely used in power, water conservancy, railway, transportation, new energy, petroleum and petrochemical, national defense, construction and urban infrastructure and other fields.
The company is headquartered in Zhengzhou, and has set up 8 branches in Beijing, Wuhan, Xi 'an, Hefei, etc., responsible for the sales and after-sales work in and around the region. In 2013, the group wholly established Henan JinFar East Cable Co., LTD., responsible for the international market sales and expansion business, products are exported to the Americas, Africa, Australia, Europe and other 38 countries and regions, products by foreign customers praise.
With the continuous expansion of product share, Xinfeng cable products have also been widely recognized and praised by the majority of users, The company has successively won the industry "National quality integrity enterprise", "China Famous products", "Henan famous brand products", 2013-2015 successively won the Henan Provincial Bureau of Industry and Commerce "contract-abiding and trustworthy enterprise", "quality, service, credit AAA enterprise", "National product quality supervision and sampling inspection qualified enterprise" and other honors.
1.Advanced Production Equipment:Advanced production equipment and testing equipment, including more than 200 sets of advanced cable production equipment.Medium voltage cable production equipment uses the German Sikora brand.
2.Quality Control:The factory has well-equipped quality control room,can complete the inspection of all major electrical parameters.
3.Experienced Team:Our experienced production and sales teams can respond to a wide variety of projects, quickly respond to customer needs, and are able to provide type test reports for most major products.
4.Competitive Pricing:Our pricing competitive without compromising on quality.
Q:What factors should be considered when selecting a power cable?
A:Factors include voltage rating, current carrying capacity, environmental conditions (temperature, moisture, chemicals), mechanical stresses (such as impact or vibration), installation requirements, and regulatory standards.Our sales team can assist in selecting the appropriate cable based on these factors.
Q:What types of power cables do you offer?
A:We offer a wide range of power cables including low voltage (voltages up to 1000V.), medium voltage (1000V to 35 kV.). We also provide specialty cables such as fire-resistant, armored, and flexible cables to meet various customer needs.