Product Description
1. Main Application
XLPE(Cross linked polyethylene) cable constitutes the best cable for transmission and distribution lines because of its excellent electrical and physical properties. These cables has the advantage of simplicity in construction, lightness in weight; convenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with no limitation of level difference along the route.
2. Standards
GB/12706.2, IEC60502-2,BS 6622 , VDE 0276, HD 620 S1,NFC 33-226, IS 1554 , IS 7098 and ICEA S-66-524 etc.
* Xinfeng Cable can also design and produce for special application requirement.
3. Product PropertiesThe product is suitable for power transmission and distribution lines with rated power frequency voltage 6kV~35 kV.
3.1 Rated voltages U0/U(Um): 3.6/6(7.2)kV,6/10(12) kV, 8.7/15(17.5) kV, 12/20(24) kV, 18/30(36) kV; 21/35(40.5) kV; 26/35(40.5) kV;
Note: The above rated voltages are equivalent to 3.8/6.6(7.2)kV,6.35/11(12) kV, 8.7/15(17.5) kV, 12.7/22(24) kV, 19/33(36) kV;
U0 :Rated power-frequency voltage between conductor and earth or armour, metal sheath or screen for which the cable is suitable.
U :Rated power-frequency voltage between phase conductors for which the cable is suitable.
Um :Maximum value of the highest system voltage between phase conductors for which the cable is suitable.
3.2 The ambient temperature for installation: ≥0ºC
3.3 Maximum conductor temperature in normal operation:≤90ºC
3.4 Max operating temperature of con. When cable short-circuited(5s maximum duration): 250ºC
3.5 Permissible minimum bending radius:
Single unarmoured cable: 20 x OD
Multi-core unarmoured cable: 15 x OD
Single armoured cable: 5 x OD
Multi-core armoured cable: 12 x OD
Note : OD=Overall Diameter of Cable
For full technical specifications and for details of the 6kV~30kV cable, please refer to the datasheets or speak to our sales team for more advice.
Detailed Photos
Product Parameters
4. Product Type
Chinese Type |
General Type |
VDE Type |
Description |
Application |
YJV (YJLV) |
CU/XLPE/PVC (AL/XLPE/PVC) |
N2XSY N2XSEY (NA2XSY NA2XSEY) |
Cu conductor(Al conductor)XLPE insulated PVC sheathed power cable |
Laying indoors, in tunnel, fixed on the bracket, pipe and buried in the soil, the cable can not bear external mechanical forces. |
YJY (YJLY) |
CU/XLPE/PE (AL/XLPE/PE) |
N2XS2Y N2XSE2Y (NA2XS2Y NA2XSE2Y) |
Cu conductor(Al conductor)XLPE insulated PE sheathed power cable |
YJV22 (YJLV22) |
CU/XLPE/STA/PVC (AL/XLPE/STA/PVC) |
N2XSBY N2XSEBY (NA2XSBY NA2XSEBY) |
Cu conductor(Al conductor)XLPE insulated double of steel-tape armored PVC sheathed power cable |
For laying indoors, in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
YJV23 (YJLV23) |
CU/XLPE/STA/PE (AL/XLPE/STA/PE) |
N2XSB2Y N2XSEB2Y (NA2XSB2Y NA2XSEB2Y) |
Cu conductor(Al conductor)XLPE insulated double of steel-tape armored PE sheathed power cable |
YJV62 (YJLV62) |
CU/XLPE/ATA/PVC (AL/XLPE/ATA/PVC) |
N2XSBY N2XSEBY (NA2XSBY NA2XSEBY) |
Cu conductor(Al conductor)XLPE insulated double of aluminium-tape armored PVC sheathed power cable |
YJV32 (YJLV32) |
CU/XLPE/SWA/PVC (AL/XLPE/SWA/PVC) |
N2XSRY N2XSERY (NA2XSRY NA2XSERY) |
Cu conductor(Al conductor)XLPE insulated steel-wire armored PVC sheathed power cable |
For laying indoors, in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force |
YJV33 (YJLV33) |
CU/XLPE/SWA/PE (AL/XLPE/SWA/PE) |
N2XSR2Y N2XSER2Y (NA2XSR2Y NA2XSER2Y) |
Cu conductor(Al conductor)XLPE insulated steel-wire armored PE sheathed power cable |
YJV72 (YJLV72) |
CU/XLPE/AWA/PVC (AL/XLPE/AWA/PVC) |
N2XSRY N2XSERY (NA2XSRY NA2XSERY) |
Cu conductor(Al conductor)XLPE insulated aluminium-wire armored PE sheathed power cable |
If the cable model you want is not in the list, please contact our sales team to get more.
5. Range of production
Chinese Type |
General Type |
VDE Type |
No.of cores |
3.6/6(7.2) |
6/6(7.2) 6/10(12.0) |
8.7/10(12) 8.7/15(17.5) |
12/20(24.0) |
18/30(36.0) |
21/35(40.5) |
26/35(40.5) |
Indicated in Table |
1 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
3 |
16-630 |
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
16-630 |
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
16-630 |
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
16-630 |
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
16-630 |
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
16-630 |
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
16-630 |
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
16-630 |
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
Note:a,The armoring materials of single core cable should use nonmagnetic materials.
b, Xinfeng Cable can produce "Flame-Retardant Series", "Fire-Resistant Series", "Low Smoke Halogen Free (LSHF/LSOH) Series","Low Smoke Low Halogen (LSLH) Series", etc. power cable as customer required.
Performance in line with IEC60332,IEC 61034,IEC60754 requirements.
6. Construction
Conductor: Plain annealed stranded compacted circular copper or aluminium conductor to IEC60228 class 2
Conductor Screen: Extruded semi-conductive compound
Insulation: XLPE (cross-linked polyethylene) rated at 90°C
Insulation Screen: Extruded semi-conductive compound
Metallic Screen: copper tape or a concentric layer of copper wires
Color for core identification: Red, Yellow, Blue tape shall be applied between insulation screen and metallic screen (The above identifying can be changed as order)
Assembly : Three screened cores are laid up together ,if necessary filled with non-hygroscopic material compatible with insulation and covered with a layer of PVC sheath
Inner Sheath: Extruded layer of PVC ST2 or PE , LSZH
Armour : Double of galvanized steel tape or galvanized steel wire for three core power cable ,Double of aluminium tape or aluminium wire for single power cable
Outer Sheath: PVC type ST2 to IEC 60502 or PE ,LSZH
7. Product Parameters and the figure of cable structure
7.1Copper or Aluminium Conductor XLPE Insulated PVC Sheathed unarmoured Power Cables For Rated Voltages up to and including 6-35kV
Single Core XLPE Insulated Unarmoured Power Cable
1: Conductor : Circular compacted stranded Copper or aluminium
2: Conductor screen:Extruded semi-conductive compound
3: Insulation : XLPE
4: Insulation screen:Extruded semi-conductive compound
5: Metallic sreen: Copper tape
6: Binder tape: non-hygroscopic material
7: Sheath : PVC
Three Core XLPE Insulated Unarmoured Power Cable
1: Conductor : Circular compacted stranded Copper or aluminium
2: Conductor screen: Extruded semi-conductive compound
3: Insulation : XLPE
4: Insulation screen: Extruded semi-conductive compound
5: Metallic screen: Copper tape
6: Binder tape: non-hygroscopic material
7: Filler : non-hygroscopic material
8: Sheath : PVC
Table 1 Single core, CU or AL conductor, XLPE insulated, PVC sheathed Power Cable, 6/10kV(6.35/11kV) to IEC60502-2
Type |
Specification |
Outer diameter |
Nominal thickness of insulation |
Nominal sheath thickness |
Approx. Outer diameter of cable |
Approx. Weight of cable |
Max. D.C. resistance of conductor at 20ºC |
Cu |
Al |
Cu |
Al |
N2XSY N2XSEY (NA2XSY NA2XSEY) |
mm2 |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
Ω/km |
Ω/km |
1×25 |
6.0 |
3.4 |
1.8 |
20.0 |
604.7 |
450.1 |
0.727 |
1.20 |
1×35 |
7.0 |
3.4 |
1.8 |
21.0 |
721.2 |
504.7 |
0.524 |
0.868 |
1×50 |
8.4 |
3.4 |
1.8 |
22.4 |
893.2 |
583.9 |
0.387 |
0.641 |
1×70 |
10.0 |
3.4 |
1.8 |
24.0 |
1115.2 |
682.1 |
0.268 |
0.443 |
1×95 |
11.5 |
3.4 |
1.8 |
25.5 |
1378.8 |
791.1 |
0.193 |
0.320 |
1×120 |
13.0 |
3.4 |
1.8 |
27.0 |
1643.1 |
900.7 |
0.153 |
0.253 |
1×150 |
14.5 |
3.4 |
1.9 |
28.6 |
1957.6 |
1029.5 |
0.124 |
0.206 |
1×185 |
16.2 |
3.4 |
1.9 |
30.4 |
2323.3 |
1178.7 |
0.0991 |
0.164 |
1×240 |
18.4 |
3.4 |
2.0 |
32.7 |
2885.5 |
1400.6 |
0.0754 |
0.125 |
1×300 |
20.5 |
3.4 |
2.1 |
35.0 |
3489.8 |
1633.7 |
0.0601 |
0.100 |
1×400 |
23.5 |
3.4 |
2.2 |
38.2 |
4483.8 |
2009.0 |
0.0470 |
0.0778 |
1×500 |
26.5 |
3.4 |
2.3 |
41.4 |
5477.7 |
2384.2 |
0.0366 |
0.0605 |
1×630 |
30.0 |
3.4 |
2.4 |
45.1 |
6759.4 |
2861.6 |
0.0283 |
0.0469 |
Table 2 Three core, CU or AL conductor, XLPE insulated, PVC sheathed Power Cable, 6/10kV(6.35/11kV) to IEC60502-2
Type |
Specification |
Outer diameter |
Nominal thickness of insulation |
Nominal sheath thickness |
Approx. Outer diameter of cable |
Approx. Weight of cable |
Max. D.C. resistance of conductor at 20ºC |
Cu |
Al |
Cu |
Al |
N2XSY N2XSEY (NA2XSY NA2XSEY) |
mm2 |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
Ω/km |
Ω/km |
3×25 |
6.0 |
3.4 |
2.3 |
40.2 |
1904.8 |
1438.4 |
0.727 |
1.20 |
3×35 |
7.0 |
3.4 |
2.3 |
42.6 |
2304.5 |
1651.6 |
0.524 |
0.868 |
3×50 |
8.4 |
3.4 |
2.4 |
45.8 |
2884.5 |
1951.8 |
0.387 |
0.641 |
3×70 |
10.0 |
3.4 |
2.6 |
49.5 |
3619.7 |
2313.9 |
0.268 |
0.443 |
3×95 |
11.5 |
3.4 |
2.7 |
52.9 |
4490.7 |
2718.6 |
0.193 |
0.320 |
3×120 |
13.0 |
3.4 |
2.8 |
56.4 |
5382.6 |
3144.1 |
0.153 |
0.253 |
3×150 |
14.5 |
3.4 |
2.9 |
59.8 |
6381.6 |
3583.5 |
0.124 |
0.206 |
3×185 |
16.2 |
3.4 |
3.0 |
63.7 |
7570.5 |
4119.5 |
0.0991 |
0.164 |
3×240 |
18.4 |
3.4 |
3.2 |
68.8 |
9341.8 |
4864.9 |
0.0754 |
0.125 |
3×300 |
20.5 |
3.4 |
3.3 |
73.6 |
11270.6 |
5674.5 |
0.0601 |
0.100 |
3×400 |
23.5 |
3.4 |
3.6 |
80.5 |
14378.7 |
6917.1 |
0.0470 |
0.0778 |
3×500 |
26.5 |
3.4 |
3.7 |
87.5 |
17555.6 |
8404.5 |
0.0366 |
0.0605 |
7.2Copper or Aluminium Conductor XLPE Insulated PVC Sheathed armoured Power Cables For Rated Voltages up to and including 6-35kV
Single core XLPE insulated armoured power cable
1: Conductor : Circular compacted stranded Copper or aluminium
2: Conductor screen:Extruded semi-conductive compound
3: Insulation : XLPE
4: Insulation screen:Extruded semi-conductive compound
5: Metallic screen: Copper tape
6: Separation tape : non-hygroscopic material
7: Inner covering(bedding):Extruded PVC
8: Metallic armour : Non-magnetic material (Aluminum wire or aluminium tape)
9: Sheath : PVC
10: Binder tape: non-hygroscopic material
Three core XLPE insulated armoured power cable
1: Conductor : Circular compacted stranded Copper or aluminium
2: Conductor screen:Extruded semi-conductive compound
3: Insulation : XLPE
4: Insulation screen:Extruded semi-conductive compound
5: Metallic screen: Copper tape
6: Binder tape: non-hygroscopic material
7: Inner covering(bedding):Extruded PVC
8: Metallic armour : Galvanized steel wire or Galvanized steel tape
9: Filler : non-hygroscopic material
10: Sheath : PVC
11: Binder tape: non-hygroscopic material
Table 3 Single core, CU or AL conductor, XLPE insulated, Aluminium wire Armored, PVC sheathed Power Cable, 6/10kV(6.35/11kV) to IEC60502-2
Type
|
Specification |
Outer diameter |
Nominal thickness of insulation |
Diameter of aluminium wire |
Nominal sheath thickness |
Approx. Outer diameter of cable |
Approx. Weight of cable |
Max. D.C. resistance of conductor at 20ºC |
CU |
AL |
CU |
AL |
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
Ω/km |
Ω/km |
N2XSRY N2XSERY (NA2XSRY NA2XSERY) |
1×25 |
6.0 |
3.4 |
1.6 |
1.8 |
25.7 |
810 |
660 |
0.727 |
1.20 |
1×35 |
7.0 |
3.4 |
1.6 |
1.8 |
26.9 |
940 |
730 |
0.524 |
0.868 |
1×50 |
8.4 |
3.4 |
1.6 |
1.8 |
28 |
1100 |
810 |
0.387 |
0.641 |
1×70 |
10.0 |
3.4 |
1.6 |
1.8 |
29.9 |
1350 |
930 |
0.268 |
0.443 |
1×95 |
11.5 |
3.4 |
1.6 |
1.9 |
31.5 |
1670 |
1080 |
0.193 |
0.320 |
1×120 |
13.0 |
3.4 |
1.6 |
1.9 |
33.9 |
1950 |
1200 |
0.153 |
0.253 |
1×150 |
14.5 |
3.4 |
1.6 |
2.0 |
35.7 |
2270 |
1350 |
0.124 |
0.206 |
1×185 |
16.2 |
3.4 |
2.0 |
2.0 |
37.3 |
2770 |
1620 |
0.0991 |
0.164 |
1×240 |
18.4 |
3.4 |
2.0 |
2.1 |
39.7 |
3440 |
1930 |
0.0754 |
0.125 |
1×300 |
20.5 |
3.4 |
2.0 |
2.2 |
41.9 |
4120 |
2210 |
0.0601 |
0.100 |
1×400 |
23.5 |
3.4 |
2.5 |
2.3 |
46.5 |
5250 |
2820 |
0.0470 |
0.0778 |
1×500 |
26.5 |
3.4 |
2.5 |
2.4 |
50.6 |
6520 |
3520 |
0.0366 |
0.0605 |
1×630 |
30.0 |
3.4 |
2.5 |
2.5 |
54.6 |
7960 |
4020 |
0.0283 |
0.0469 |
Table 4 Single core, CU or AL conductor, XLPE insulated, Aluminium tape Armored, PVC sheathed Power Cable, 8.7/15kV(8.7/10kV) to IEC60502-2
Type
|
Specification |
Outer diameter |
Nominal thickness of insulation |
Aluminium tape Layer×thickness |
Nominal sheath thickness |
Approx. Outer diameter of cable |
Approx. Weight of cable |
Max. D.C. resistance of conductor at 20ºC |
CU |
AL |
CU |
AL |
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
Ω/km |
Ω/km |
N2XSBY N2XSEBY (NA2XSBY NA2XSEBY) |
1×25 |
6.0 |
4.5 |
2×0.5 |
1.8 |
25.4 |
999.0 |
846.75 |
0.727 |
1.20 |
1×35 |
7.0 |
4.5 |
2×0.5 |
1.8 |
26.4 |
1129.7 |
917.5 |
0.524 |
0.868 |
1×50 |
8.4 |
4.5 |
2×0.5 |
1.8 |
27.8 |
1313.3 |
1016.7 |
0.387 |
0.641 |
1×70 |
10.0 |
4.5 |
2×0.5 |
1.9 |
29.5 |
1578.4 |
1157.0 |
0.268 |
0.443 |
1×95 |
11.5 |
4.5 |
2×0.5 |
1.9 |
31.2 |
1870.2 |
1292.7 |
0.193 |
0.320 |
1×120 |
13.0 |
4.5 |
2×0.5 |
2.0 |
32.7 |
2173.4 |
1443.0 |
0.153 |
0.253 |
1×150 |
14.5 |
4.5 |
2×0.5 |
2.0 |
34.3 |
2510.8 |
1593.1 |
0.124 |
0.206 |
1×185 |
16.2 |
4.5 |
2×0.5 |
2.1 |
37.4 |
2919.5 |
1783.4 |
0.0991 |
0.164 |
1×240 |
18.4 |
4.5 |
2×0.5 |
2.2 |
39.8 |
3532.6 |
2053.1 |
0.0754 |
0.125 |
1×300 |
20.5 |
4.5 |
2×0.5 |
2.3 |
42.1 |
4172.8 |
2315.6 |
0.0601 |
0.100 |
1×400 |
23.5 |
4.5 |
2×0.5 |
2.4 |
45.5 |
5166.9 |
2744.7 |
0.0470 |
0.0778 |
1×500 |
26.5 |
4.5 |
2×0.5 |
2.5 |
48.8 |
6296.3 |
3218.5 |
0.0366 |
0.0605 |
1×630 |
30.0 |
4.5 |
2×0.5 |
2.6 |
52.6 |
7631.1 |
3776.8 |
0.0283 |
0.0469 |
8. The laying of the cable ampacity correction in different environments
8.1 Laid in the air
8.1.1 Ambient temperature : 30ºC
8.1.2 Rating factors in different ambient temperature:
Ambient temperature |
20ºC |
25ºC |
30ºC |
35ºC |
40ºC |
45ºC |
50ºC |
55ºC |
60ºC |
Rating factors |
1.08 |
1.04 |
1.00 |
0.96 |
0.91 |
0.87 |
0.82 |
0.76 |
0.71 |
8.2 Directly buried in ground
8.2.1 Ambient temperature: 20ºC.
8.2.2 Thermal Resistance of Soil: 1.5k•m/W.
8.2.3 Depth of laying : 0.8m
8.2.4 Rating factors in different ambient temperature:
Ambient temperature |
10ºC |
15ºC |
20ºC |
25ºC |
30ºC |
35ºC |
40ºC |
45ºC |
50ºC |
Rating factors |
1.07 |
1.04 |
1.00 |
0.96 |
0.93 |
0.89 |
0.85 |
0.80 |
0.76 |
Packaging & Shipping
Packaging Mode 1:Wooden Drum Packing,suitable for small cross section cable.Packing length about 500 meters.
Packaging Mode 2:Steel Frame Wooden Drum Packing,suitable for big cross section cable.Packing length about 2000 meters.
Company Profile
Xinfeng Cable Co., Ltd. is a research and development, production, sales in one of the well-known wire and cable enterprises, with a complete and scientific quality management system, advanced technical team support, strong sales and after-sales service.
Henan Xinfeng Cable Co., LTD., founded in 1996, with a registered capital of 210 million CNY, covers a total area of 50,000 square meters, the existing staff of 586 people, including a variety of technical personnel more than 80 people, with a university degree 60 people, the company has the current domestic advanced production equipment and testing equipment, including more than 200 sets of advanced cable production equipment. And spend tens of millions to purchase the most complete cable testing equipment.
In 2012, the company took the lead in the cable industry through the ISO9001 international quality system certification, ISO14001 occupational safety and health certification system, 18001 environmental management certification, national CCC compulsory certification and other qualifications, and through the European safety product CE certification, European environmental protection ROSH certification, SGS environmental protection product testing certification. In 20 years of development, it has formed an annual production capacity of 1.5 billion CNY for overhead insulated wires, high and low voltage cables, BV cables and other products, and constantly improve and expand the research and development and production field of cable products.
At present, the company is mainly engaged in the system design, development, manufacturing, marketing and service of more than 1000 kinds of cables in four categories: overhead wire, power cable, electrical equipment wire and cable, and special cable. Products are widely used in power, water conservancy, railway, transportation, new energy, petroleum and petrochemical, national defense, construction and urban infrastructure and other fields.
The company is headquartered in Zhengzhou, and has set up 8 branches in Beijing, Wuhan, Xi 'an, Hefei, etc., responsible for the sales and after-sales work in and around the region. In 2013, the group wholly established Henan JinFar East Cable Co., LTD., responsible for the international market sales and expansion business, products are exported to the Americas, Africa, Australia, Europe and other 38 countries and regions, products by foreign customers praise.
With the continuous expansion of product share, Xinfeng cable products have also been widely recognized and praised by the majority of users, The company has successively won the industry "National quality integrity enterprise", "China Famous products", "Henan famous brand products", 2013-2015 successively won the Henan Provincial Bureau of Industry and Commerce "contract-abiding and trustworthy enterprise", "quality, service, credit AAA enterprise", "National product quality supervision and sampling inspection qualified enterprise" and other honors.
Our Advantages
1.Advanced Production Equipment:Advanced production equipment and testing equipment, including more than 200 sets of advanced cable production equipment.Medium voltage cable production equipment uses the German Sikora brand.
2.Quality Control:The factory has well-equipped quality control room,can complete the inspection of all major electrical parameters.
3.Experienced Team:Our experienced production and sales teams can respond to a wide variety of projects, quickly respond to customer needs, and are able to provide type test reports for most major products.
4.Competitive Pricing:Our pricing competitive without compromising on quality.
FAQ
Q:What factors should be considered when selecting a power cable?
A:Factors include voltage rating, current carrying capacity, environmental conditions (temperature, moisture, chemicals), mechanical stresses (such as impact or vibration), installation requirements, and regulatory standards.Our sales team can assist in selecting the appropriate cable based on these factors.
Q:What types of power cables do you offer?
A:We offer a wide range of power cables including low voltage (voltages up to 1000V.), medium voltage (1000V to 35 kV.). We also provide specialty cables such as fire-resistant, armored, and flexible cables to meet various customer needs.
Q:What are the benefits of buying power cables from your company?
A:We provide high-quality cables manufactured to international standards.Our cables are durable, reliable, and designed to meet specific application requirements.We offer competitive pricing and flexible delivery options to meet project timelines.Our experienced team provides technical support and advice to ensure the right cable selection for your project.
Q:Can I request samples of your power cables before making a purchase?
A:Yes, we can provide samples of our power cables for evaluation purposes. Sample availability may vary depending on the type and specifications of the cable. Contact our sales team to request samples and discuss shipping arrangements.
Q:Do you provide documentation and support for product certifications required for government tender or public sector projects?
A:Yes, we offer documentation and support to assist with product certifications required for government or public sector projects. Our team can help navigate regulatory requirements, provide compliance documentation, and ensure that our power cables meet specific project specifications and standards.